TILTON, AR, USA
N8421V
Rockwell S2R
THE COMMERCIAL PLT SAID THAT WHILE EN ROUTE TO THE FIELD TO BE TREATED, THE ENGINE BEGAN TO LOSE POWER. AN EMERGENCY LNDG WAS MADE IN A SOFT, WET, FARM FIELD, WHICH RESULTED IN SUBSTANTIAL DAMAGE TO THE ACFT. POST-ACCIDENT INVESTIGATION REVEALED THE ENGINE DRIVEN SUPERCHARGER HAD FAILED.
FAILURE OF THE ENGINE BLOWER(SUPERCHARGER). RELATED TO THE ACCIDENT WAS THE SOFT/WET TERRAIN, WHERE THE FORCED LANDING WAS PERFORMED.