BALTIMORE, MD, USA
N236AA
McDonnell Douglas MD-80
MAIN LANDING GEAR UPPER TORQUE LINK ATTACH BOLT SEPARATED DURING TAKEOFF AS A RESULT OF PREEXISTING STRESS CORROSION CRACKING. MCDONNELL-DOUGLAS ISSUED ALERT MD-80 SERVICE BULLETIN A32-220 FOLLOWING THE INCIDENT.
Source: NTSB Aviation Accident Database