HOUSTON, TX, USA
N3903W
PIPER PA-32-260
THE ACFT DEVELOPED A FIRE IN THE ENG AREA DURING THE INITIAL CLIMB AFTER TAKEOFF. WHEN THE ENG LOST POWER THE PLT ATTEMPTED A LNDG IN A SMALL PARK. THE ACFT TOUCHED DOWN JUST SHORT OF A DRAINAGE DITCH AND COLLIDED WITH THE SLOPING EMBANKMENT ON THE OPPOSITE SIDE OF THE DITCH. POST ACC INSPECTION REVEALED A FAILED EXHAUST SYSTEM WHICH ALLOWED HOT EXHAUST GASES TO START A FIRE. THE EXHAUST PIPE FAILED FROM EXTENSIVE CORROSION.