THE ACFT WAS BASED AT AN UNCONTROLLED AIRSTRIP WITHOUT FUEL FACILITIES. PRIOR TO TAKE-OFF, THE PLT REFUELED THE ACFT FROM A 5 GAL CAN AND DRAINING THE FUEL SUMPS. DURING AN APPROACH TO LAND AT CONWAY, SC, THE ACFT LOST POWER AND A FORCED LANDING WAS MADE ON A ROAD. REPORTEDLY, THE ACFT STALLED AT ABOUT 10 TO 12 FT AGL AS THE PLT MANEUVERED TO AVOID CARS AND POWERLINES. AN INSPECTION OF THE ACFT CONFIRMED THE FUEL WAS CONTAMINATED WITH WATER, RUST AND DIRT. THERE WAS NO EVIDENCE OF A MECHANICAL MALFUNCTION.