BILLINGS, MT, USA
N3889S
BELL 206L-3
WHILE ON TAKEOFF FROM A HOSPITAL ROOF TOP HELIPAD ON AN EMERGENCY MEDICAL SERVICE FLT, A SYNCHRONIZED ELEVATOR COVER BLEW OFF AND STRUCK THE TAIL ROTOR. THIS RESULTED IN AN INFLIGHT SEPARATION OF ONE TAIL ROTOR BLADE AND A LOSS OF ANTI-TORQUE CONTROL. THE PLT EXECUTED AN AUTOROTATION IN THE URBAN AREA WITH NO SUITABLE TERRAIN FOR AN EMERGENCY FORCED LANDING.