HUTCHINSON, KS, USA
N617CA
BEECH 95-B55
DURING ARRIVAL, THE PLT BEGAN AN ILS APCH TO RWY 13 AT THE HUTCHINSON MUNI ARPT. HE REPORTED THAT HE HAD TURNED OFF THE 16 MI ARC, HAD INTERCEPTED THE LOCALIZER & HAD BEGUN HIS DESCENT TO THE MIN PUBLISHED ALT TO CROSS OVER THE OUTERMARKER (FINAL APCH FIX). JUST PRIOR TO REACHING THE OUTER MARKER, THE ACFT COLLIDED WITH THE 2 TOP STATIC WIRES OF A POWER LINE, THEN CRASHED TO THE GROUND. DURING AN EXAM OF THE ACFT, THE ALTIMETER WAS FOUND INDICATING 8400 FT. IT WAS TAKEN TO A REPAIR STATION FOR A TEARDOWN, BUT WAS READING -3500 FT BY THEN. A DISASSEMBLY & EXAM OF THE ALTIMETER WAS MADE, BUT ITS PREIMPACT CONDITION & ITS READ-OUT AT IMPACT COULD NOT BE DETERMINED.
Source: NTSB Aviation Accident Database
Aviation Accidents App