BANDON, OR, USA
N5543
PIPER PA-24-250
THE PLT WAS FERRYING THE ACFT TO BANDON TO HAVE THE LANDING GEAR REPAIRED. THE FLT WAS MADE WITH THE GEAR SECURED IN THE DOWN POSITION. THE ACFT HAD LOCKING FUEL CAPS & THE PLT DID NOT VISUALLY CHECK THE FUEL LEVEL BEFORE TAKING OFF; INSTEAD, HE RELIED OF THE FUEL GAGES. DURING FLT, THE PLT USED FUEL FROM THE LEFT TANK THEN SWITCH TO THE RIGHT TANK WHICH INDICATED ABOUT 1/2 FULL. A SHORT TIME LATER, AS THE ACFT WAS APPROACHING THE DESTINATION ARPT, THE ENG LOST POWER FROM FUEL EXHAUSTION. SUBSEQUENTLY, THE ACFT WAS DAMAGED DURING AN EMERGENCY LANDING JUST SHORT OF THE RWY.
Source: NTSB Aviation Accident Database