CRAWFORDSVILLE, IN, USA
N2124R
CESSNA 182G
PLT STATED THAT WHILE EN ROUTE THE GENERATOR CIRCUIT BREAKER POPPED AND ATTEMPTS TO RESET IT PROVED FUTILE. A LOSS OF PWR OCCURRED LATER IN THE FLT AND A FORCED LANDIG WAS MADE IN A FIELD DURING WHICH THE ACFT WAS DAMAGED. NO FUEL WAS FOUND IN THE ACFT AFTER THE ACCIDENT OCCURRED. PLT STATED HE FORGOT TO REFUEL THE ACFT BEFORE DEPARTING.