CHESANING, MI, USA
N597HJ
JORDAN ACEY DEUCY
THIS WAS THE FIRST FLIGHT OF THE HOMEBUILT. SHORTLY AFTER TAKEOFF THE ENG QUIT DUE TO INADEQUATE GROUNDING. THE PLT RETURNED TO THE FIELD & MADE A SMOOTH LANDING. AT THE END OF THE ROLL OUT THE ANCHOR PLATE FOR THE LANDING GEAR TRUSS FAILED CAUSING THE LEFT GEAR TO COLLAPSE. THE PLT STATED THAT THE 3/4 INCH X 0.049, 4130 SQUARE TUBING USED FOR THE ANCHOR PLATE WAS TOO LIGHT TO CARRY THE ACFT LOADING & THAT IT MAY HAVE BEEN PREVIOUSLY CRACKED FROM HIGH SPEED TAXI TESTS.
Source: NTSB Aviation Accident Database