Aviation Accident Summaries

Aviation Accident Summary LAX04LA277

San Diego, CA, USA

Aircraft #1

N5167R

Cessna 172RG

Analysis

The right main landing gear collapsed during rollout following a normal touchdown on the runway. Thereafter, directional control was lost, and the right wing struck the surface of the runway. The airplane veered off the runway, and it came to rest in an adjacent open dirt field. During flight the pilot had experienced a low voltage condition, and his radio communications became problematic as the battery gradually discharged. The pilot cycled the airplane's master electric system switch in accordance with instructions in the Cessna Pilot's Operator's Handbook. Because this did not restore electric power, the pilot reduced the electrical load to conserve energy. No evidence of any mechanical malfunction was found during the post impact examination of the landing gear and alternator/battery electric system. During the examination the alternator field circuit breaker was found in the tripped position. The examination revealed that when the alternator circuit breaker was reset, electric current was restored to the buss and the battery was charging. Prior to landing, the pilot failed to properly perform procedures relating to ensuring that the alternator circuit breaker was engaged. Also, the pilot failed to ensure that the landing gear was fully extended by using the emergency gear extension system.

Factual Information

On July 23, 2004, about 2003 Pacific daylight time, a Cessna 172RG, N5167R, was substantially damaged during landing rollout following the partial collapse of its main landing gear at the Montgomery Field, San Diego, California. The private pilot was not injured. The airplane was operated by San Diego Flight Training International, Inc., San Diego. Visual meteorological conditions prevailed at the time of the private pilot's solo instructional flight. An instrument flight plan was filed. The flight was performed under the provisions of 14 CFR Part 91, and it originated from San Diego about 1910. The pilot reported to the National Transportation Safety Board investigator that the purpose of the flight was to practice flying in furtherance of attaining a commercial pilot certificate. No anomalies were observed when the flight originated. Eventually, however, the pilot observed that the airplane's alternator was registering a discharge condition, and his radio communications became problematic. In the pilot's verbal and subsequent written statement he reported, in pertinent part, that approaching the Montgomery Field he cycled the airplane's master (electrical system) switch in accordance with instructions in the Cessna Pilot's Operator's Handbook. Because this did not completely restore electric power, he reduced the electric load to conserve energy. The pilot asserted that he lowered the landing gear and observed the corresponding green "gear down and locked" light illuminate. During the approach, no landing gear warning horn was heard. The pilot additionally indicated that he landed on runway 28R without use of the landing light. The touchdown was normal. During rollout the right main landing gear collapsed, directional control was lost, and the right wing struck the surface of the runway. The airplane veered right off the runway, and it came to rest in an adjacent open dirt field. At the direction of the Safety Board investigator, a Federal Aviation Administration (FAA) certificated airframe and powerplant mechanic with inspection authority examined the airplane. The mechanic reported that the airplane's battery power was low. An external power supply was connected to the airplane, and the landing gear was retracted and extended. The landing gear was retracted again, during which the aural warnings interconnected with the throttle position were checked. No anomalies were noted. The landing gear warning horn was functional and it operated properly. The emergency landing gear extension system was checked and was also found to be functional. No evidence of any mechanical malfunction was noted during the tests. The mechanic further reported that the airplane's battery was charged, and the airplane's engine was started. Thereafter, the ammeter showed a discharge and the low voltage light on the panel illuminated. The alternator circuit breaker was found popped. The breaker was reset and the alternator came on line, the low voltage light extinguished, and a positive charge was noted. All accessories and lights were turned on, and the alternator circuit breaker remained set. The FAA coordinator opined to the Safety Board investigator that during the flight the pilot had failed to properly perform procedures relating to ensuring that the alternator circuit breaker was engaged. Also, the pilot failed to ensure that the landing gear was fully extended by using the emergency gear extension system.

Probable Cause and Findings

The pilot's failure to ensure that the landing gear was fully extended, by use of the emergency gear extension system, which resulted in its partial collapse during landing rollout. Also causal was the pilot's failure to follow POH procedures relating to troubleshooting and restoring electric power to the airplane busses.

 

Source: NTSB Aviation Accident Database

Get all the details on your iPhone or iPad with:

Aviation Accidents App

In-Depth Access to Aviation Accident Reports