Avalon, TX, USA
N409SB
BELL 214ST
The helicopter was on its third test flight when the tail rotor 90-degree gearbox broke in two and separated from the helicopter. The crew conducted an autorotation to a field, and the helicopter came to rest on its side. Examination of the helicopter and components revealed that one of the tail rotor's two counterweight bellcranks and associated hardware were missing. Impact marks consistent with a counterweight bellcrank were found at the base of its associated tail rotor blade and on the aft right side of the helicopter. The remaining counterweight bellcrank was in place; however, the cotter pin for the castellated nut was missing. A review of the aircraft maintenance records revealed that the tail rotor assembly had been removed and reinstalled after the installation of test instrumentation. The maintenance records lacked specific details on whether the unit and its components were previously handled as a subassembly or as individual components when the tail rotor assembly was initially removed. Because the records did not indicate whether the unit should be handled as individual parts, the tail rotor was reinstalled as a complete subassembly, meaning that individual components, such as the nut and cotter pin, were not individually inspected before or after reinstallation on the helicopter. Reinstalling the tail rotor assembly in this manner led to the counterweight bellcrank retaining nut not being properly torqued and secured with a cotter pin.
On August 7, 2012, about 0845 central daylight time, a Bell 214ST helicopter, N409SB, experienced a loss of tail rotor authority near Avalon, Texas. The commercial and airline transport pilots were not injured during the precautionary landing, and the helicopter was substantially damaged. The helicopter was owned and operated by Bell Helicopter, Textron, Inc. Fort Worth, Texas, under the provisions of 14 Code of Federal Regulations Part 91 as a research and development flight. Day visual meteorological conditions prevailed for the local flight which operated without a flight plan. The local flight originated from the Arlington Municipal Airport (KGKY), Arlington, Texas at 0815. According to the pilots the purpose of the flight was to collect data on the helicopter's rotor system. During the flight test, the helicopter completed a right turn and as they were setting up for another test condition, the pilot's heard a "bang," and felt the helicopter yaw. The pilot of the chase aircraft reported that something had departed the tail of the helicopter. The accident pilots then initiated an autorotation to a nearby field; however, helicopter yawed, rolled right, and came to rest on its side. The helicopter, the tail rotor gear box, and tail rotor blades were recovered and transported back to a Bell facility. Representatives from the NTSB, Federal Aviation Administration (FAA), and Bell Helicopter, then examined the helicopter and components at the manufacturer's facility. The tail rotor's 90-degree gear box was broken in two; one of the mast's two counterweight bellcranks and associated hardware were missing (and not located/recovered from the accident site); the remaining counterweight bellcrank remained attached. Examination of the remaining counterweight bellcrank, revealed that the assembly was in place, but "loose". The dustcap/grease cover for the remaining counterweight bellcrank was removed, exposing the castellated nut. The examination found that the nut's cotterpin was missing. Both tail rotor blades' attachments remained in place; both blades had separated outboard of their respective attachments. On the side with the missing counterweight bellcrank, impact marks consistent with the size and shape of a counterweight bellcrank, were found on the edge and base of its associated tail rotor blade, as well as on the right side of the helicopter. The rotor blade was torn in two, with the separation starting near the impact marks at the base of the blade. Since the accident helicopter was used to collect data on a new rotor system, the tail rotor blades and components had been removed to install test instrumentation. A review of the helicopters' maintenance workbook revealed the temporary re-installation of the instrumented tail rotor section. However, the maintenance entry was not specific as to whether the reinstallation of the instrumented tail rotor assembly was conducted as an assembly or as individual components. The mechanics installing the instrumented tail rotor treated the unit as a complete sub-assembly and not as individual components. The difference meant that the individual components were not assembled or inspected, prior to or after installation onto the helicopter. The helicopter was on its third flight after the reinstallation of the instrumented tail rotor system and had accumulated about 2.8 flight hours, before the accident.
Maintenance personnel’s failure to properly torque the retaining nut and install the cotter pin that secured the helicopter’s tail rotor counterweight bellcrank. Contributing to the accident was the lack of detailed maintenance records that documented previous maintenance actions.
Source: NTSB Aviation Accident Database
Aviation Accidents App
In-Depth Access to Aviation Accident Reports